Description

Smart sensitive head transfers data immediately on PC. Original applications software collects data, analyzes and plots results of your measurements. No need for addition power supply and cooling - joulemeter probe is powered through the USB port on computer.

Pulse Radiation Energy Meter VEP-1 is compatible with PC-AT and newer type computer and is connected to it via USB port requiring no separate analyzing block.

Joulemeter probe includes pyroelectric sensitive element with 10 mm active area diameter. Thick-film combined absorbing coating yields spectral response from 0.2 to 12 and repetition rate from a single pulse up to 2000 pps. When a radiation pulse falls on the pyroelectric sensitive element, it generates an electric current pulse with magnitude proportional to the energy of the radiation pulse. Built-in matching amplifier, microcontroller, and central processor, together give real-time output of calculated results to PC via USB connection interface for following processing and visualization.

After completion of the needed calculations, microcontroller transfers to PC package containing information concerning pulse energy value, time span between pulses, pulse sequence number, and device status word.

The PC-compatible software records calibration data and device functioning parameters, controls device working regimes, calculates and visualizes measurement state and results (energy, average power, and measured pulses repetition rate).

TECHNICAL SPECIFICATIONS

  • Wavelength Range, μm –––––––––––––––––––––––––––––––  0.2 *· 12
  • Energy Range, μj ––––––––––––––––––––––––––––––––––––  0.1 + 100 (1 + 1000 with attenuator)
  • Max Energy Density, μj/cm2 –––––––––––––––––––––––––––  20
  • Max Repetition Rate, pps –––––––––––––––––––––––––––––  2000
  • Max Pulse Width, ps ––––––––––––––––––––––––––––––––– 10
  • Detector –––––––––––––––––––––––––––––––––––––––––––  Pyroelectric (LiTaO3)
  • Active Area Diameter, mm ––––––––––––––––––––––––––––– 10
  • PC Connection Interface Type –––––––––––––––––––––––––– USB 2.0
  • Power Consumption, W ––––––––––––––––––––––––––––––– 0.5 (Via USB Interface)
  • Operation Temperature Range, °С ––––––––––––––––––––––– +5 to +40
  • Operation Relative Humidity (no more than), % –––––––––––– 95
  • Device Size, (diameter x height), mm ––––––––––––––––––– 100 x 60
  • Device Weight, kg ––––––––––––––––––––––––––––––––––– 0.5

Innovative Aspect and Main Advantages

  • Real-time monitoring of small energies of coherent and noncoherent pulse radiation;
  • Ideal for labs with limited budget for buying both detector and meter;
  • Perfect for labs with inadequate space for peripheral equipment installation;
  • Unique for labs requiring instrumentation with high sensitivity coupled with improved operation speeds;
  • No need for power supply and cooling;
  • Stable and reliable, can stand heat, mechanicals and radiation impacts in difficult operational conditions.
  • Direct real-time monitoring of output radiation allows to perform a feedback stability control of this radiation on demanding applications (e.g. hard tissue operations welding of plastics and cutting/ metals);
  • Ideal for labs with limited budget for buying both detector and meter;
  • Perfect for labs with inadequate space for peripheral equipment installation as we can measure energy without the need to install beam splitters and deviators thus producing considerable space economies and experimentation simplifications;
  • Unique for labs requiring instrumentation with very high sensitivity coupled with increased power and improved operating speeds;
  • No need for Power supply and cooling;
  • Stable and reliable, can stand more heat, mechanical and radiation impacts in difficult operational conditions than it is usual with other Pyroelectric meters based on Lithium Tantalate crystals.

Pyroelectric USB All-in-One Detector and Energy Meter: VEP-1
Fig. 1 Pyroelectric USB All-in-One Detector and Energy Meter: VEP-1

Areas of Application

Pulse All-in-One USB Radiation Energy Meter VEP-1 is designed for measurement of small energies both of single and repetitive (up to 2000 pps) pulses coherent and non-coherent radiation in a wide spectral band of wavelength (0,2 +12 μm).



Contact Details

Technology Transfer Office
Organization: Institute of Physics
Adress: 46, Nauky Avenue, 03680, Kyiv, Ukraine
(+38 044) 525 9841, Fax: (+38 044)525 1589
This e-mail address is being protected from spambots. You need JavaScript enabled to view it

Add comment


Security code
Refresh

For additional technologies go to: http://www.stcu.int